PWM Controller PCB Type
PWM controller
none
PCB Type

General Specifications

model No. PWMController(PCBType)
Material PCB: FR-4
Size 80(H)× 45(W)× 17(D)
Expected Life
Motor Construction
Motor Protection System
Dielectric Strength
Dielectric Strength (With Sensor)
Insulation Resistance
Sound Pressure Level (SPL)
Lead Wire
Sensor-Purpose Lead Wire
Connector
Contact
Fail-safe
Storage Temperature
Operating Temperature -20℃ to +70℃
Operating Voltage Range
Output PWM signal VOH (high level voltage): 3.3 or 5 VDC (selectable),
Frequency: 25 kHz
No. of connectable fans Up to 4 fans
Mounting method Screw mounting
Power consumption[W] 0.2*1
Mass 27g
G-force tolerance
Surface treatment
Applicable models
PPI(Indicates the number of holes per inch.)
Power cord length(mm)
Applicable standards

Features

Reduces system power consumption and fan noise
For PWM fan speed control, a PWM control circuit needs to be newly designed and configured.
By using this product, however, PWM control function fans can be fully utilized without the need for preparing new circuits, contributing to reducing the system power consumption and the fan noise.

Can be common-powered by the fan power supply
The controller can be powered by the fan power supply of rated voltage 12, 24, and 48 VDC, and no separate supply is required.

Maximum of four fans connectable
Up to four fans with PWM control function can be connected and controlled.

9PC8045D-T001
· Models with the following sensor specifications are also available as options:
· Please inquire as the availability of these options depends on the model.
The following nos. have .
Other sensor specifications are . Please refer to the index. Please refer to the index.

Specifications

Model No.Airflow
direction
Voltage
[V]
Rated
Voltage
[V]
Operating
Voltage Range
[V]
PWM
duty
cycle
[%]
Frequency
[Hz]
Input
[W]
Current
[A]
Locked
Rotor
Current
[A]
Rated
Current
[A]
Rated
Input
[W]
Rated
Speed
[min-1]
Rated
Speed
[min-1]
Rated
Speed
[min-1]
Inlet
Rated
Speed
[min-1]
Outlet
Max. Airflow
[m3/min]
Max. Airflow
[CFM]
Max. Static
Pressure
[Pa]
Max. Static
Pressure
[inchH2O]
θc-a
Thermal
Resistance
[K/W]
SPL
[dB(A)]
Expected
Life
[h]
Control functionsOrder no.FanVoltageLow-speedsensorSensor specificationsPlug cordFingerguardsMounting screws
9PC8045D-V001

7 to 60

9PC8045D-R001

7 to 60

9PC8045D-T001

7 to 60

Model no. 9PC8045D-V001 9PC8045D-R001 9PC8045D-T001
Size [mm] 80 (H) ×45 (W) ×17 (D)
Rated voltage [V] 12 / 24 / 48
Power consumption [W] 0.2*1
Operating temperature [℃] -20 to +70
Input terminal Input voltage range [V] (V+, V-) 7 to 60
Control voltage range [V] 0 to 5.5
Output terminal PWM signal output VOH (high level voltage): 3.3 or 5 VDC selectable
PWM frequency [kHz] 25
Output current 20 mA max. (total sum of 4 terminals)
Output breakdown voltage [V] 6.5
No. of connectable fans Up to 4 fans
Control functions*2 Voltage control Variable resistor control*3 Thermistor control*3
Mounting method Screw mounting
Mass [g] 27
Material PCB: FR-4

*1:When output terminals are turned on

*2:Control functions are mutually exclusive for BOX type.

*3:Variable resistor and thermistor are not supplied with the controller and need to be prepared separately.

Be noted that if applied input voltage or frequency is out of range of the connected fan, how the fan speed responds to the PWM duty cycle may be altered.

Front View (component names)

Front View (component names)

Connection Examples and PWM Signal Output Characteristics

Controller can be common-powered by the power supply for 12, 24, and 48 VDC rated voltage fans. It can also be powered by a separate supply as long as both supplies share the same ground.

・ Voltage control   Output duty cycle controlled with input voltage of 0 to 5 VDC *Ensure that the input voltage does not exceed 5.5 VDC.

Voltage control

・ External adjustment (variable resistor) control   Output duty cycle controlled with variable resistor connected to terminals

External adjustment (variable resistor) control

・ Thermistor control Automatic control of output duty cycle in response to the temperature detected with an external thermistor

Thermistor control

Dimensions (unit: mm)

Dimensions

Set Models

Option

Set configuration items