SANYO DENKI(山洋電気) PRODUCTS

SANUPS PV Inverter SANUPS P83E
P83E104SFC

  • Eco Products
  • Grid-connected operation
  • Isolated operation
  • Meets FRT requirements
  • With Output Control function

For illustrative purposes only

Specifications

Model No.
P83E104SFC
Rated input voltage[V]
DC300
Max. allowable input voltage[V]
DC600
Input operating voltage range[V]
DC240 ~ 600
Rated output capacity[kW]
100
Rated output capacity - During isolated operation[kW]
100
MPPT input voltage range[V]
DC240~550
No. of output phases/wires
3-phase 3-wire
Rated output voltage[V]
AC202
Output voltage regulation
Isolated operation: Within ±8% of rated voltage
Rated output frequency[Hz]
50/60
Output frequency regulation
Isolated operation: Within ±0.1 Hz of rated frequency
Output current harmonic distortion
Grid-connected operation: Total ≤ 5%, individual ≤ 3% Isolated operation: 5% or less at linear load
Output overload capability
100% continuous
Output power factor
0.95 or greater. Power factor setting range: 0.8 to 1.0 (in increments of 0.01))
Main circuit type
Self-commutated voltage type
Switching method
High-frequency PWM
Isolation method
High-frequency isolation
Efficiency
95%
Cooling method
Forced air cooling
Grid protection
Overvoltage (OVR), undervoltage (UVR), overfrequency (OFR), underfrequency (UFR)
Islanding detection - Passive method
Voltage phase jump detection
Islanding detection - Active method
Reactive power variation method
Acoustic noise[dB]
63 max.
Operating temperature
-10~+60℃
Operating humidity
30 to 90% (non-condensing)
Operating altitude (maximum)
2000m
Mass[kg]
1030
PV inverter operating panel

Download Materials List

Login is required to download
Materials Material No. File Size Download Link
Catalog Download

Applicable Models

Model no. Item Name
PVMB Remote Monitoring Service PV Monitor Type C

Related Information

Options

Item Name
Outdoor cubicle
Power distribution box for inverter unit number control, 2 circuits
Power distribution box for inverter unit number control, 3 circuits
Power distribution box for inverter unit number control, 4 circuits
Power distribution box for inverter unit number control, 5 circuits
Isolated output Scott-T transformer 10 kVA
Isolated output Scott-T transformer 20 kVA
Junction box
Weather signal conversion box
Contacts
  •  
License Agreement

This license agreement is a legal agreement between the customer and SANYO DENKI CO., LTD. and its subsidiaries (hereinafter referred to as "SANYO DENKI Group") regarding SANYO DENKI CO., LTD. software (hereinafter referred to as "the software").

The customer may download this software only upon consenting to this agreement.

1. License Grants

SANYO DENKI Group grants the customer the nonexclusive right to use this software. The customers may use, install, and update the software while using the product purchased from the SANYO DENKI Group.

The customer may not lend or transfer this software to a third party nor offer it as collateral without obtaining prior written approval from SANYO DENKI Group. In addition, if the customer lends or transfers the software to a third party with prior written approval of SANYO DENKI Group, the customer must ensure that the third party complies with the provisions of this agreement.

2. Copyrights and Intellectual Property Rights

SANYO DENKI retains all copyrights, patent rights, trademark rights, know-how, and all other intellectual property rights related to this software and relevant printed materials (including electronic media).

3. Warranty Coverage

SANYO DENKI Group guarantees the operation and functions described in the instruction manual for this software. However, the warranty does not cover the software in the following cases:

  1. (1) The software is used in unsupported operating environments or with unsupported products.
  2. (2) The software is used in a manner other than as specified in the instruction manual.
  3. (3) The software is modified.
4. Legal Disclaimer

SANYO DENKI Group and its distributors are not liable for any damages outside the scope of warranty as stated in this license agreement.

SANYO DENKI Group is not responsible for any malfunction caused by installing or updating this software in unsupported operating environments or with unsupported products.

5. Jurisdiction

Any disputes arising in the fulfillment of this agreement shall be settled by the Tokyo District Court as the exclusive competent court.

6. Governing Law

This agreement shall be governed by the laws of Japan.