DB16H782D |
2-Phase Stepping Set Models |
□60 |
1.37 |
|
0.4 |
2 |
Bipolar |
|
|
|
|
24/36 VDC ±10% |
3 |
16 |
Pulse train |
DB16H782S |
2-Phase Stepping Set Models |
□60 |
1.37 |
|
0.4 |
2 |
Bipolar |
|
|
|
|
24/36 VDC ±10% |
3 |
16 |
Pulse train |
DB16S162D |
2-Phase Stepping Set Models |
□60 |
1.28 |
|
0.4 |
2 |
Bipolar |
|
|
|
|
24/36 VDC ±10% |
3 |
16 |
Pulse train |
DB16S162S |
2-Phase Stepping Set Models |
□60 |
1.28 |
|
0.4 |
2 |
Bipolar |
|
|
|
|
24/36 VDC ±10% |
3 |
16 |
Pulse train |
PBA1P603 |
Closed Loop Stepping Set Models |
□60 |
|
|
0.4 |
|
|
Incremental |
|
|
|
Single-phase 100 to 115 VAC (-15%, +10%), 50/60 Hz |
6 |
|
Pulse train |
PBA1P603-C10 |
Closed Loop Stepping Set Models |
□60 |
|
3 |
0.4 |
|
|
Incremental |
Low-backlash gear |
1:10 |
|
Single-phase 100 to 115 VAC (-15%, +10%), 50/60 Hz |
6 |
|
Pulse train |
PBA1P603-C20 |
Closed Loop Stepping Set Models |
□60 |
|
3.5 |
0.4 |
|
|
Incremental |
Low-backlash gear |
1:20 |
|
Single-phase 100 to 115 VAC (-15%, +10%), 50/60 Hz |
6 |
|
Pulse train |
PBA1P603-C3.6 |
Closed Loop Stepping Set Models |
□60 |
|
1.25 |
0.4 |
|
|
Incremental |
Low-backlash gear |
1:3.6 |
|
Single-phase 100 to 115 VAC (-15%, +10%), 50/60 Hz |
6 |
|
Pulse train |
PBA1P603-C30 |
Closed Loop Stepping Set Models |
□60 |
|
4 |
0.4 |
|
|
Incremental |
Low-backlash gear |
1:30 |
|
Single-phase 100 to 115 VAC (-15%, +10%), 50/60 Hz |
6 |
|
Pulse train |
PBA1P603-C7.2 |
Closed Loop Stepping Set Models |
□60 |
|
2.5 |
0.4 |
|
|
Incremental |
Low-backlash gear |
1:7.2 |
|
Single-phase 100 to 115 VAC (-15%, +10%), 50/60 Hz |
6 |
|
Pulse train |
PBA1R603 |
Closed Loop Stepping Set Models |
□60 |
|
|
0.4 |
|
|
Incremental |
|
|
|
Single-phase 100 to 115 VAC (-15%, +10%), 50/60 Hz |
6 |
|
RS-485+Parallel I/O |
PBA1R603-C10 |
Closed Loop Stepping Set Models |
□60 |
|
3 |
0.4 |
|
|
Incremental |
Low-backlash gear |
1:10 |
|
Single-phase 100 to 115 VAC (-15%, +10%), 50/60 Hz |
6 |
|
RS-485+Parallel I/O |
PBA1R603-C20 |
Closed Loop Stepping Set Models |
□60 |
|
3.5 |
0.4 |
|
|
Incremental |
Low-backlash gear |
1:20 |
|
Single-phase 100 to 115 VAC (-15%, +10%), 50/60 Hz |
6 |
|
RS-485+Parallel I/O |
PBA1R603-C3.6 |
Closed Loop Stepping Set Models |
□60 |
|
1.25 |
0.4 |
|
|
Incremental |
Low-backlash gear |
1:3.6 |
|
Single-phase 100 to 115 VAC (-15%, +10%), 50/60 Hz |
6 |
|
RS-485+Parallel I/O |
PBA1R603-C30 |
Closed Loop Stepping Set Models |
□60 |
|
4 |
0.4 |
|
|
Incremental |
Low-backlash gear |
1:30 |
|
Single-phase 100 to 115 VAC (-15%, +10%), 50/60 Hz |
6 |
|
RS-485+Parallel I/O |
PBA1R603-C7.2 |
Closed Loop Stepping Set Models |
□60 |
|
2.5 |
0.4 |
|
|
Incremental |
Low-backlash gear |
1:7.2 |
|
Single-phase 100 to 115 VAC (-15%, +10%), 50/60 Hz |
6 |
|
RS-485+Parallel I/O |
PBA2P603 |
Closed Loop Stepping Set Models |
□60 |
|
|
0.4 |
|
|
Incremental |
|
|
|
Single-/3-phase 200 to 230 VAC (-15%, +10%), 50/60 Hz |
Single-phase: 4.5 , 3-phase: 2.5 |
|
Pulse train |
PBA2P603-C10 |
Closed Loop Stepping Set Models |
□60 |
|
3 |
0.4 |
|
|
Incremental |
Low-backlash gear |
1:10 |
|
Single-/3-phase 200 to 230 VAC (-15%, +10%), 50/60 Hz |
Single-phase: 4.5 , 3-phase: 2.5 |
|
Pulse train |
PBA2P603-C20 |
Closed Loop Stepping Set Models |
□60 |
|
3.5 |
0.4 |
|
|
Incremental |
Low-backlash gear |
1:20 |
|
Single-/3-phase 200 to 230 VAC (-15%, +10%), 50/60 Hz |
Single-phase: 4.5 , 3-phase: 2.5 |
|
Pulse train |
PBA2P603-C3.6 |
Closed Loop Stepping Set Models |
□60 |
|
1.25 |
0.4 |
|
|
Incremental |
Low-backlash gear |
1:3.6 |
|
Single-/3-phase 200 to 230 VAC (-15%, +10%), 50/60 Hz |
Single-phase: 4.5 , 3-phase: 2.5 |
|
Pulse train |