Frame size[mm]
|
Frame thickness[mm]
|
Rated voltage[V]
|
Rated current[A] |
Rated input[W] |
Rated speed[min-1] |
Max. airflow[m3/min] |
Max. airflow[CFM] |
Max. static pressure[Pa] |
Max. static pressure[inchH2O] |
SPL[dB(A)] |
Expected life[h] |
Sensor type |
IP rating |
PWM control function |
Ribbed |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9CT1-001 | San Ace Controller | No | No | ||||||||||||||
9PC8045D-R001 | PWM Controller | No | No | ||||||||||||||
9PC8045D-T001 | PWM Controller | No | No | ||||||||||||||
9PC8045D-V001 | PWM Controller | No | No | ||||||||||||||
9PC8666X-S001 | PWM Controller | No | No | ||||||||||||||
9CT1-T | Temperature / Humidity sensor | No | No | ||||||||||||||
9CT1-P | Air pressure sensor | No | No | ||||||||||||||
9CT1-A | Accelerometer | No | No | ||||||||||||||
109-1106 | Inlet nozzle | φ70 | No | No | |||||||||||||
109-1080H | Inlet nozzle | φ100 | No | No | |||||||||||||
109-1146H | Finger guard | φ270 | No | No | |||||||||||||
9CT1-002 | San Ace Controller | No | No | ||||||||||||||
9CT1-U001 | San Ace Controller | No | No | ||||||||||||||
9PC8045D-R101 | PWM Controller | No | No | ||||||||||||||
9PC8045D-T101 | PWM Controller | No | No | ||||||||||||||
9PC8045D-V101 | PWM Controller | No | No | ||||||||||||||
9PC8666X-S101 | PWM Controller | No | No | ||||||||||||||
109S006UL | AC Fan | 120 | 38 | 100 115 | 0.1/0.09 0.13/0.11 | 7/7 10/10 | 1650/1700 1800/1900 | 1.45/1.5 1.56/1.64 | 51.2/53 55/57.9 | 17.6/17.6 20/20.6 | 0.071/0.071 0.08/0.083 | 28/28 30/31 | 25000/60℃ (56000/40℃) | Without pulse sensor | No | No | |
109-040UL | AC Fan | 80 | 42 | 100 | 0.13/0.11 | 10/9 | 2650/3100 | 0.85/1.0 | 30.0/35.3 | 24.5/35.3 | 0.098/0.142 | 40/44 | 25000/60℃ (56000/40℃) | Without pulse sensor | No | No | |
109-047UL | AC Fan | 80 | 42 | 100 | 0.05/0.05 | 4/3.5 | 1500/1500 | 0.43/0.43 | 15.2/15.2 | 8.8/8.8 | 0.035/0.035 | 24/24 | 25000/60℃ (56000/40℃) | Without pulse sensor | No | No |
Model no.
|
Product name
|
Frame size[mm]
|
Frame thickness[mm]
|
Rated voltage[V]
|
Rated current[A] |
Rated input[W] |
Rated speed[min-1] |
Max. airflow[m3/min] |
Max. airflow[CFM] |
Max. static pressure[Pa] |
Max. static pressure[inchH2O] |
SPL[dB(A)] |
Expected life[h] |
Sensor type |
IP rating |
PWM control function |
Ribbed |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9CT1-001 | San Ace Controller | No | No | ||||||||||||||
9PC8045D-R001 | PWM Controller | No | No | ||||||||||||||
9PC8045D-T001 | PWM Controller | No | No | ||||||||||||||
9PC8045D-V001 | PWM Controller | No | No | ||||||||||||||
9PC8666X-S001 | PWM Controller | No | No | ||||||||||||||
9CT1-T | Temperature / Humidity sensor | No | No | ||||||||||||||
9CT1-P | Air pressure sensor | No | No | ||||||||||||||
9CT1-A | Accelerometer | No | No | ||||||||||||||
109-1106 | Inlet nozzle | φ70 | No | No | |||||||||||||
109-1080H | Inlet nozzle | φ100 | No | No | |||||||||||||
109-1146H | Finger guard | φ270 | No | No | |||||||||||||
9CT1-002 | San Ace Controller | No | No | ||||||||||||||
9CT1-U001 | San Ace Controller | No | No | ||||||||||||||
9PC8045D-R101 | PWM Controller | No | No | ||||||||||||||
9PC8045D-T101 | PWM Controller | No | No | ||||||||||||||
9PC8045D-V101 | PWM Controller | No | No | ||||||||||||||
9PC8666X-S101 | PWM Controller | No | No | ||||||||||||||
109S006UL | AC Fan | 120 | 38 | 100 115 | 0.1/0.09 0.13/0.11 | 7/7 10/10 | 1650/1700 1800/1900 | 1.45/1.5 1.56/1.64 | 51.2/53 55/57.9 | 17.6/17.6 20/20.6 | 0.071/0.071 0.08/0.083 | 28/28 30/31 | 25000/60℃ (56000/40℃) | Without pulse sensor | No | No | |
109-040UL | AC Fan | 80 | 42 | 100 | 0.13/0.11 | 10/9 | 2650/3100 | 0.85/1.0 | 30.0/35.3 | 24.5/35.3 | 0.098/0.142 | 40/44 | 25000/60℃ (56000/40℃) | Without pulse sensor | No | No | |
109-047UL | AC Fan | 80 | 42 | 100 | 0.05/0.05 | 4/3.5 | 1500/1500 | 0.43/0.43 | 15.2/15.2 | 8.8/8.8 | 0.035/0.035 | 24/24 | 25000/60℃ (56000/40℃) | Without pulse sensor | No | No |