Online UPS SANUPS A11K-Li
S-A11KL302B0050TSN00
- Eco Products
- Vertical type
- Rack mount type
- Input plug
- Output outlet
For illustrative purposes only
Specifications
- Model No.
- S-A11KL302B0050TSN00
- UPS topology
- Double conversion online
- No. of input phases/wires
- Single-phase 2-wire
- Rated input voltage[V]
- 100/110/120
- Input voltage range
- At load level < 70%: Within -40% to +20% of rated voltage (-40% becomes -20% for recovery voltage)
At load level ≥ 70%: Within ±20% of rated voltage
- Rated input frequency[Hz]
- 50/60
- Input frequency range
- Within ±1/3/5/7% of rated frequency (same as output frequency regulation)
- Input power factor
- 0.97 or greater
- Required input capacity[kVA]
- 3.0
- No. of output phases/wires
- Single-phase 2-wire
- Rated output capacity[kVA]
- 3
- Rated output capacity[kW]
- 2.4
- Rated output voltage[V]
- 100/110/120
- Output voltage regulation
- Within ±2% of rated voltage (at rated output)
- Rated output frequency[Hz]
- 50/60
- Output frequency regulation
- During grid operation: Within ±1/3/5/7% of rated frequency (User-selectable)
During battery operation: Within ±0.5% of rated frequency
- Output transient voltage fluctuation
- For abrupt load change: Within ±5% of rated voltage (for 0⇔100% load step changes)
For loss or return of input power: Within ±5% of rated voltage (at rated output)
For abrupt input voltage change: Within ±5% of rated voltage (for ±10% voltage changes)
- Output overcurrent protection
- Automatic transfer to bypass (With automatic retransfer function)
- Output overload capability
- Inverter: 105% (for 200 ms)
Bypass: 200% (for 30 s), 800% (for 2 cycles)
- Inverter
- High-frequency PWM
- Energy storage device type
- Lithium-ion battery
- Standard backup time[min]
- 50
- Cooling method
- Forced air cooling
- Operating temperature range
- -20 ~ +55℃
- Operating humidity range
- 10 to 90% (non-condensing)
- EMC standard
- VCCI 32-1 Class-A
- Acoustic noise[dB]
- 55
- Heat dissipation[W]
- 254
- Mass[kg]
- 74
Download Materials List
Applicable Models
Model no. | Item Name |
---|---|
PMS52A00DL | UPS management software (Windows version) SANUPS SOFTWARE Download version |
PMS52A00DL-10 | UPS management software (Windows version, 10 licenses) SANUPS SOFTWARE Download version |
PMS52A00DL-100 | UPS management software (Windows version, 100 licenses) SANUPS SOFTWARE Download version |
PMS52A00DL-50 | UPS management software (Windows version, 50 licenses) SANUPS SOFTWARE Download version |
PMS53A00DL | UPS management software (Multi-OS version) SANUPS SOFTWARE Download version |
PMS53A00DL-10 | UPS management software (Multi-OS version, 10 licenses) SANUPS SOFTWARE Download version |
PMS53A00DL-100 | UPS management software (Multi-OS version, 100 licenses) SANUPS SOFTWARE Download version |
PMS53A00DL-50 | UPS management software (Multi-OS version, 50 licenses) SANUPS SOFTWARE Download version |
PRCONIF005 | Dry contact interface card (Terminal block) |
PRCONIF006 | Dry contact interface card (D-sub 15-pin) |
PRLANIF013B | Power Management Product - LAN Interface Card (Supports IPv6 and temperature/humidity sensors) |
PRLANIF022A | Power Management Product - LAN Interface Card (IPv6, Modbus TCP supported, with cover) |
PRLANIF024A | Power Management Product - LAN Interface Card (IPv6, Modbus TCP/RTU supported, with cover) |
PRLANIF031 | Power Management Product - LAN Interface Card (1-Gigabit Ethernet Supported) |
Related Information
Options
Item Name |
---|
Remote switch, 10 m (RSW015) |
Remote switch, 2 m (RSW016) |
Linked Operation cable, for branching; terminal connection (P10911) |
Linked Operation cable, 1 m cable (P10912) |
Linked Operation cable, 3 m cable (P10913) |
3U rack support rails (RM027) |
4U rack support rails (RM028) |
Floor mounting brackets (FMBCA01) |
Air filter (FL009-3) |