Specifications
- Model No.
 - E11BL102A002AUJ
 
- UPS topology
 - Hybrid
 
- No. of input phases/wires
 - Single-phase 2-wire
 
- Rated input voltage[V]
 - 200/208/220/230/240
 
- Input voltage range
 - During Double Conversion mode
At load level < 40% ... 110 to 300 V
At load level < 70% ... 136 to 288 V
At load level ≥ 70% ... 160 to 288 V During Economy mode
Within ±8% of rated voltage 
- Rated input frequency[Hz]
 - 50/60
 
- Input frequency range
 - In Double Conversion mode fixed setting
Within ±1% of rated frequency (Synchronization range)
40 to 120 Hz (Asynchronous operation range)
In automatic transfer setting
Within ±1/3/5% of rated frequency (Factory setting is ±3%, synchronization range)
40 to 120 Hz (Asynchronous operation range) 
- Input power factor
 - 0.95 or greater
 
- Required input capacity[kVA]
 - 1.1
 
- No. of output phases/wires
 - Single-phase 2-wire
 
- Rated output capacity[kVA]
 - 1
 
- Rated output capacity[kW]
 - 0.8
 
- Rated output voltage[V]
 - 200/208/220/230/240
 
- Output voltage regulation
 - Double Conversion mode: Within ±2% of rated voltage
Economy mode: Within -10% to +8% of rated voltage 
- Rated output frequency[Hz]
 - 50/60
 
- Output frequency regulation
 - In Double Conversion mode fixed setting: Within ±1% of rated frequency
In automatic transfer setting: Within ±1/3/5% of rated frequency (Factory setting: ±3%)
During battery operation: Within ±0.5% of rated frequency (This applies in asynchronous operation too) 
- Output transient voltage fluctuation
 - At abrupt load change: Within ±5% of rated voltage (For 0⇔100% load step changes)
At loss/return of input power: Within ±5% of rated voltage (At rated output)
At abrupt input voltage change: Within ±5% of rated voltage (For ±10% voltage changes) 
- Output overcurrent protection
 - Automatic transfer to bypass (With automatic retransfer function)
 
- Output overload capability
 - Inverter: 105% (for 200 ms)
Bypass: 200% (for 30 s), 800%(for 2 cycles) 
- Energy storage device type
 - Lithium-ion battery
 
- Expected battery (device) life
 - Approx. 10 years
 
- Standard backup time[min]
 - 4
 
- Cooling method
 - Forced air cooling
 
- Operating temperature range
 - -10 ~+55℃
 
- Operating humidity range
 - 20 to 90% (non-condensing)
 
- EMC standard
 - VCCI 32-1 Class A
FCC Part15 Sub partB Class A
EN62040-2 C2: 2010,
EN55022: 2010 Class A,
EN62040-2: 2006,
EN55024: 2010 
- Acoustic noise[dB]
 - 51
 
- Heat dissipation[W]
 - 130
 
- Mass[kg]
 - 12
 
Download Materials List
| Materials | Material No. | File Size | Download Link | 
|---|---|---|---|
| 取扱説明書 | M0020305 | 7.9 MB | Login required | 
| ユーザ設定説明書 | M0020196 | 8.0 MB | Login required | 
| Instruction Manual | M0020306 | 7.7 MB | Login required | 
| Setting Menu Manual | M0020197 | 8.0 MB | Login required | 
| Manuel d'utilisation | M0020307 | 8.3 MB | Login required | 
| Manuel des menus de réglage | M0020389 | 8.6 MB | Login required | 
If there are any differences in the descriptions in Japanese, English or French, Japanese shall prevail.
Related Information
Options
| Item Name | 
|---|
| Vertical stands (STAND2UA00) | 
| 2U rack support rails (RM030) | 
        
      
    