Specifications
- Model No.
- E11B202A001DMT
- UPS topology
- Hybrid
- No. of input phases/wires
- Single-phase 2-wire
- Rated input voltage[V]
- 100/110/115/120
- Input voltage range
- During Double Conversion mode
At load level < 40% ... 55 to 150 V
At load level < 70% ... 68 to 140 V
At load level ≥ 70% ... 80 to 140 V
During Economy mode: Within ±8% of rated voltage
- Rated input frequency[Hz]
- 50/60
- Input frequency range
- In Double Conversion mode fixed setting
Within ±1% of rated frequency (Synchronization range)
40 to 120 Hz (Asynchronous operation range)
In automatic transfer setting
Within ±1/3/5% of rated frequency (Factory setting is ±3%, synchronization range)
40 to 120 Hz (Asynchronous operation range)
- Input power factor
- 0.95 or greater
- Required input capacity[kVA]
- 2.2
- No. of output phases/wires
- Single-phase 2-wire
- Rated output capacity[kVA]
- 2
- Rated output capacity[kW]
- 1.6
- Rated output voltage[V]
- 100/110/115/120
- Output voltage regulation
- Double Conversion mode: Within ±2% of rated voltage
Economy mode: Within -10% to +8% of rated voltage
- Rated output frequency[Hz]
- 50/60
- Output frequency regulation
- In Double Conversion mode fixed setting
Within ±1% of rated frequency
In automatic transfer setting: Within ±1/3/5% of rated frequency (Factory setting: ±3%)
During battery operation: Within ±0.5% of rated frequency (This applies in asynchronous operation too)
- Output transient voltage fluctuation
- At abrupt load change: Within ±5% of rated voltage (For 0⇔100% load step changes)
At loss/return of input power: Within ±5% of rated voltage (At rated output)
At abrupt input voltage change: Within ±5% of rated voltage (For ±10% voltage changes)
- Output overcurrent protection
- Automatic transfer to bypass (With automatic retransfer function)
- Output overload capability
- Inverter: 105% (for 200 ms)
Bypass: 200% (for 30 s), 800%(for 2 cycles)
- Energy storage device type
- Small-sized valve-regulated lead-acid (VRLA) battery
- Expected battery (device) life
- Approx. 5 years
- Standard backup time[min]
- 3 (5)
- Cooling method
- Forced air cooling
- Operating temperature range
- -10 ~+55℃
- Operating humidity range
- 20 to 90% (non-condensing)
- EMC standard
- VCCI ClassA
- Acoustic noise[dB]
- 55
- Heat dissipation[W]
- 260
- Mass[kg]
- 25
- Remarks
- Factory setting: Fixed to Double Conversion mode
Note 1: The battery backup time is calculated at a 25°C ambient temperature, 0.8 load power factor, using new, fully charged batteries. The value in parentheses is calculated at a load power factor of 0.7. Note 2: The acoustic noise is for when in Double Conversion mode.
Download Materials List
Applicable Models
Model no. | Item Name |
---|---|
PMS52A00DL | UPS management software (Windows version) SANUPS SOFTWARE Download version |
PMS52A00DL-10 | UPS management software (Windows version, 10 licenses) SANUPS SOFTWARE Download version |
PMS52A00DL-100 | UPS management software (Windows version, 100 licenses) SANUPS SOFTWARE Download version |
PMS52A00DL-50 | UPS management software (Windows version, 50 licenses) SANUPS SOFTWARE Download version |
PMS53A00DL | UPS management software (Multi-OS version) SANUPS SOFTWARE Download version |
PMS53A00DL-10 | UPS management software (Multi-OS version, 10 licenses) SANUPS SOFTWARE Download version |
PMS53A00DL-100 | UPS management software (Multi-OS version, 100 licenses) SANUPS SOFTWARE Download version |
PMS53A00DL-50 | UPS management software (Multi-OS version, 50 licenses) SANUPS SOFTWARE Download version |
PRCONIF007 | Dry contact interface card (Terminal block) |
PRCONIF008 | Dry contact interface card (D-sub 15-pin) |
PRLANIF013B | Power Management Product - LAN Interface Card (Supports IPv6 and temperature/humidity sensors) |
PRLANIF022A | Power Management Product - LAN Interface Card (IPv6, Modbus TCP supported, with cover) |
PRLANIF024A | Power Management Product - LAN Interface Card (IPv6, Modbus TCP/RTU supported, with cover) |
PRLANIF031 | Power Management Product - LAN Interface Card (1-Gigabit Ethernet Supported) |
Related Information
Options
Item Name |
---|
Vertical stands (STAND2UA00) |
Floor mounting brackets (FM2UA00) |
Rack support rails (RM030) |
Replacement battery pack (S-BPE11B202A0003) |
Air filter(FL011) |
External battery Box(BCE11B202A01) |